Methods and Results: The method comprises two steps. First, based on the dose equivalence principle, the experimentally obtained C-E of one drug was used to calculate the equally effective C-E of the other drug at no interactivity; the resulting two zero-interactivity C-E formed the upper and lower boundaries of Additivity Envelope. Next, 95% confidence intervals calculated from experimental data were added to Additivity Envelope to obtain Uncertainty Envelope (UE). Experimentally observed effects of drug combinations (C-Ecomb,observed) located within UE indicate additivity whereas C-Ecomb,observed located above or below UE indicate statistically significant (p<0.05) synergy or antagonism, respectively. Additional in silico studies demonstrated the shape and size of Additivity Envelope, which determines the ability to detect drug interactivity, depended on the Drug A-to-B concentration ratios and the ratios of their C-E curve shape parameter. Analyses of experimental results of combinations of drugs with nonparallel C-E and/or unequal Emax indicated UE as more versatile and provided more information, compared to earlier methods.
Conclusion: UE is a broadly applicable method for analysis, including statistical significance assessment, of drug interactivity.